Independent cleanroom performance testing to verify environmental conditions, airflow performance, and cleanliness levels in accordance with applicable cleanroom standards.
Suitable for operational and live cleanroom environments
Structured testing with clear documentation and reporting
Cleanroom Performance Testing (CPT) is the systematic testing and verification of cleanroom environments to confirm that critical environmental parameters meet defined performance criteria.
Our CPT services support facility owners, QA teams, and operations personnel in verifying cleanroom conditions for operation, qualification, routine monitoring, or investigation purposes.
Testing is conducted under defined operating states, such as at-rest or operational, depending on site requirements and testing objectives.
Cleanroom environments rely on controlled airflow, filtration, pressure relationships, and cleanliness to support sensitive operations and processes.
Cleanroom performance testing helps organisations to:
Cleanroom performance testing may include the following parameters, depending on site scope and standards applied:
Cleanliness & Contamination Control
Airflow & Filtration Performance
Environmental Conditions
Pressure & Recovery
Visual & Functional Assessment
Test parameters are selected based on cleanroom design, usage, and applicable standards.
Cleanroom performance testing is carried out with reference to recognised cleanroom standards, which may include :
Testing scope and acceptance criteria are confirmed prior to execution.
Cleanroom performance testing is commonly conducted:
Cleanroom testing is conducted using a structured and controlled approach to ensure accuracy and repeatability.
We review cleanroom design criteria, operating states, standards, and testing objectives to establish the testing scope.
Testing is coordinated with site teams to ensure cleanroom readiness and stable operating conditions.
Cleanroom tests are conducted using calibrated instruments and standardised procedures.
Test results are reviewed against defined acceptance criteria
A detailed cleanroom performance testing report is issued, documenting methods, results, and observations.
Testing frequency depends on cleanroom usage, internal QA requirements, and operational risk. Many facilities conduct periodic verification to ensure continued performance.
Yes. Testing can be conducted under at-rest or operational conditions, depending on objectives and coordination.
Testing provides measured data and findings. Corrective actions, if required, can be planned separately.
Duration depends on cleanroom size, number of rooms, and test parameters. Most testing is completed within planned site windows.
Yes. All testing instruments used are calibrated and suitable for cleanroom testing applications.
IAQ Facility Services Sdn Bhd
Block E-10-21, Plaza Mont Kiara
2, Jalan Kiara, Mont Kiara,
50480 Kuala Lumpur, Malaysia.
© 2026 IAQ Facility Services Sdn.Bhd. All Rights Reserved